产品中心
Product Center
热门搜索:
NPW-160在线TP/TN/COD分析仪 可同时测量TP、TN、COD
SDI-47手动SDI污染指数测定仪
Labsen 241-6SANXIN 半微量样品PH电极
GTDO-500PPB在线微量溶氧仪
GT SDI国产SDI污染指数测定仪
GTPH30经济型便携式PH测定仪
GTOX-700便携式微量溶氧分析仪
GTOX-610经济型便携式微量溶氧仪
GTCON30便携式电导率/TDS/盐度仪
9385100DR900便携式多参数水质分析仪
GTDR系列多功能数控消解仪
哈希总磷试剂
GTAT SDI全自动污染指数测定仪
GTPH40台式pH/ORP计
58700-34PC II硅离子水质分析仪 1-100mg/L SiO2
哈希余氯试剂

LXV404.99.00302
产品简介
product
产品分类Standardized controller eliminates the need for a variety of dedicated controllers. Operates 1 or 2 sensors reducing inventory. Multi-channel controller operates either 1 or 2 sensors reducing inventory holding costs, and providing an inexpensive option to add a second sensor at a later time. Plug and Play operation with all Hach digital sensors. True dual sensor controller provides 4-20 mA outputs to transmit primary and secondary measurement values
New display and guided calibration procedures reduce operator error. Password protected SD card reader offers a simple solution for data download and transfer. Visual warning system provides critical alerts
Hach offers the largest portfolio of sensors and analyzers for water analytics with MODBUS RS232, MODBUS RS485 and Profibus® DP capability.
Non-Contact Ultrasonic Flow Sensor with pulse echo technology requires no routine maintenance.
Controller, Mounting Hardware, Basic User Manual
Analog Output Functional Mode:Linear, Logarithmic, Bi-linear, PID
Analog Outputs:Two (Five with optional expansion module) to isolated current outputs, max 550 Ω, Accuracy:± 0.1% of FS (20mA) at 25 °C, ± 0.5% of FS over -20 °C to 60 °C range
Operational Mode: measurement or calculated value
Communication:MODBUS RS232/RS485, PROFIBUS DPV1, or HART 7.2 optional
Dimensions (H x W x D):5.7 in x 5.7 in x 7.1 in (144 mm x 144 mm x 181 mm)
Display:Graphic dot matrix LCD with LED backlighting, transreflective
Display Resolution:240 x 160 pixels
Display Size:1.9 x 2.7 in. (48 mm x 68 mm)
Electrical Certifications:EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
- Hazardous Location Class I, Division 2, Groups A,B,C & D (Zone 2, Group IIC) per FM 3600 / FM 3611 & CSA C22.2 No. 213 M1987 with approved options and appropriay rated Class I, Division 2 or Zone 2 sensors
cULus safety mark
- General Locations per UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Enclosure Rating:NEMA 4X/IP66
Length:7.1 in ( 181 mm )
Manual Languages:Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Material Enclosures:Polycarbonate
Aluminium (powder coated)
Stainless Steel
Memory Backup:Flash memory
Mounting Configurations:Wall
Pole
Panel Mounting
Operating Temperature Range:-20 to 60 °C at 0 to 95% RH (non-condensing)
Power Requirements (Hz):50 - 60 Hz
Power Requirements (Voltage):100 - 240 V AC
Relay Functions:Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning
Relay: Operational Mode:Primary or secondary measurement, calculated value (dual channel only) or timer
Relays:Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Storage Conditions:-20 °C to 70 °C
Temperature Range:-20 to 70 °C, 0 to 95% RH non-condensing
Warranty:2 years
Weight:3.75 lbs. (1.70 kg)