产品简介
product
产品分类Hach's patented* APA 6000 Low-Range Hardness Analyzer accuray and continuously measures up to two sample streams for low levels (50 µg/L to 10 mg/L) of soluble hardness. Using a precise colorimetric method, the instrument performs an analysis every four minutes. It delivers continuous, accurate, and dependable performance with minimal cost for operation and maintenance. * U.S. Patent 5849592
The APA 6000 Low-Range Hardness Analyzer is designed specifically for reliable and continuous analysis at low concentrations. Use it to establish an automatic system for monitoring softener performance in industrial, ultrapure, and water treatment processes.
The APA 6000 Hardness Analyzer can be used to monitor both influent and effluent in industrial applications and water treatment processes including demineralizer effluent, boiler feed-water, boiler water, and process water. It is also appropriate for monitoring hardness in ultrapure processes used by pharmaceutical, electronic chip, and cosmetics manufacturers.
The interface of the APA 6000 Hardness Analyzer is menu-driven with on-screen prompting, self-test diagnostics, security provisions, and flexible data logging options. Simple menus (available in English, French, German or Spanish) guide the user through each step of operation.
Two separate sample streams can be monitored with the APA 6000 Hardness Analyzer when used with additional sample sequencing kits.
APA6000 LR Hardness analyzer, installation kit, one month's supply of reagents, a maintenance kit, a sample conditioning kit, Hach user manual.
Accuracy:± 5 % of reading or ± 0.03 mg/L whichever is greater
Alarm:Two SPDT relays with contacts rated for 5A resistive load at 230 Vac. Additional relays available with optional Signal Output Modules.
Certifications:NRTL certified to UL and CSA standards and CE approved
Cycle Time:4 min
Drain Fitting:3/4 NPT barbed hose fitting
Inlet Pressure:0.5 to 30.0 psig (0.03 to 2.04 bar)
Length:21 in ( 533 mm ) (522 mm)
Outputs:Two 4-20 mA outputs suitable for recorders or PID control. Ouput span programmable over any portion of the measuring range (130 Vac isolation from earth ground)
Power Requirements (Hz):50/60 Hz
Power Requirements (Voltage):90 - 240 V AC
Range:0.05 to 10 mg/L for hardness as calcium carbonate
Ranges:to for hardness as calcium carbonate
Repeatability:± 3 % of reading or ± 0.03 mg/L, whichever is greater
Response Time:Less than 5 min for 90% response
Sample Flow Rate:100 to 2000 mL/min max
Sample Temperature:5 to 50 °C (41 to 122°F)
Weight:56.22 lbs. (25.5 kg)