Nominal Cell Constant (K) = 0.05, 1/2 inch NPT Kynar (PVDF) Compression Fitting, 7m (23 ft) Digital Cable, Titanium Electrode

产品型号:
更新时间:2025-03-09
厂商性质:经销商
访问量:977
详细介绍在线留言

High Performance Design

These enhanced performance sensors are manufactured to exacting tolerances using high quality, rugged materials for demanding applications, including ultra-pure water, clean-in-place (CIP), and boiler/condensate monitoring. Each sensor is tested to determine its unique, absolute four-digit cell constant. Simply key in this constant (Hach’s easy DRY-CAL™ method) when configuring the analyzer to ensure the highest possible measuring accuracy. Each sensor also has a Pt 1000 RTD temperature element built into its tip for exceptionally fast response to changes in temperature with ±0.1ºC accuracy.

Resistivity and Conductivity Measurement Capability

These enhanced performance sensors measure from 0.057 µS/cm or 18.2 MΩ (theoretically pure water) up to 200,000 µS/cm.

Versatile Mounting Styles

Compression Fitting Sensors--
Feature titanium electrodes and a compression fitting for universal installation with up to 4 inches (102 mm) insertion depth. The 1/2-inch or 3/4-inch male NPT compression fitting are offered in Kynar® (PVDF) or 316 stainless steel. A longer version of this sensor is available for use with a 316 stainless steel ball valve hardware assembly to insert/retract the sensor form the process without stopping the flow. The longer version can also be used for insertion through a compression fitting. Maximum insertion depth is 7 inches (178 mm).
Non-Metallic General Purpose Sensors--
Have graphite electrodes and 3/4-inch male NPT threaded Ryton® bodies. Mount into a standard 3/4-inch pipe tee, 1-1/2-inch Hach union hardware (for 10 Cell Constant sensor only), or fasten onto the end of the pipe.
High Pressure and High Temperature Sensors--
Are designed for monitoring boiler water and condensate in return lines. They have 316 stainless steel electrodes and threaded bodies (3/4-inch male NPT). They can be fastened into a boiler wall using a 3/4-inch weldolet or mounted into a process line using a standard 3/4-inch stainless pipe tee.
Sanitary Clean-in-Place (CIP) Style Sensors--
Have 316 stainless steel electrodes and an integral 1-1/2-inch or 2-inch flange. These sensors can be installed using standard sanitary mounting hardware.

What's in the box

Includes: sensor with cable and manual

Specifications

Accuracy:± 2 % of reading above 200 µS/cm

Cable Length:Standard Probe Cable Length (integral)Digital Probe: 7 m (23 ft.)

Length:Digital Probe: 0.3 in ( 7 ) m (23 ft.)

Operating Temperature Range:-20 to 200 °C

Pressure Limit:0 to 300 psi (20.7 BAR)

Repeatability:± 0.5 of reading

Response Time:90 % of reading within 30 seconds of step change

Temperature Compensation:Temperature Compensator: Pt 1000 RTD

Temperature Measurement:-20 to 200 °C (–4 to 392°F)

Transmission Distance:100 m