产品中心
Product Center
热门搜索:
SDI-47手动SDI污染指数测定仪
NPW-160在线TP/TN/COD分析仪 可同时测量TP、TN、COD
Labsen 241-6SANXIN 半微量样品PH电极
GTDO-500PPB在线微量溶氧仪
GT SDI国产SDI污染指数测定仪
GTOX-700便携式微量溶氧分析仪
GTPH30经济型便携式PH测定仪
GTCON30便携式电导率/TDS/盐度仪
GTOX-610经济型便携式微量溶氧仪
GTDR系列多功能数控消解仪
9385100DR900便携式多参数水质分析仪
GTAT SDI全自动污染指数测定仪
哈希总磷试剂
GTPH40台式pH/ORP计
ZR-3620AZR-3620A小流量气体采样器
58700-34PC II硅离子水质分析仪 1-100mg/L SiO2
当前位置:首页
产品中心
水质分析仪器
其他水质分析仪及配件
LXV437.99.00002

LXV437.99.00002
产品简介
product
产品分类AISE sc ISE Ammonium Probe
USD Price: Contact Hach
AISE sc Low cost ISE Ammonium probe with RFID technology
USD Price: Contact Hach
Continuous trending of ammonium levels to control the nitrification process in municipal wastewater treatment plants with less than 30% industrial waste. Exclusively from Hach, CARTRICAL technology reduces interferences, providing greater accuracy. Must be connected to a sc200 or sc1000 Controller to form a complete system.
The Hach NH4D sc Ammonium Sensor uses an ion-selective electrode (ISE) to detect ammonium ions (NH4+) directly in the aeration basin as ammonium nitrogen (NH4-N). A pHD (differential pH) electrode is used as the reference electrode for superior stability. The most significant potential interference is from potassium ions (K+) which is compensated through the use of an integrated potassium ISE to correct the ammonium value. Potential interferences are further reduced using CARTRICAL technology. CARTRICAL calibrates each electrode individually and calibrates all three electrodes to each other. A temperature sensor is also included to improve accuracy.
The NH4D sc sensor is designed for immersion directly in the aeration basin eliminating the need for sample preparation. It installs quickly outdoors without special housing. The sensor can easily be relocated to various locations for greater knowledge about the process.
The NH4D sc sensor uses a calibrated sensor cartridge that should be replaced approximay twice a year (in typical operating conditions). No electrolyte or reagents to change. Cartridge replacement only takes minutes - just remove the old cartridge, plug in the new, and enter the sensor code. Maintenance is also minimized because sample pumps, valves, tubing, and filtration devices are not needed.
Real time measurements of ammonium in the aeration basin can be used to more effectively control the nitrification process. The low purchase price makes the NH4D sc the perfect tool for providing more visibility into daily trends to enable optimization of nutrient removal.
A specially-designed air cleaning unit is available for the NH4D sc sensor. Air is directed at each of the three individual electrodes for optimal cleaning. A compact compressor is available to provide pressurized air for the cleaning unit with weather-proof housing suitable for tank-side installation without additional structural requirements.
Nitrate probe, sensor cartridge, user manual
Accuracy:5 % of measured value +0.2 mg/L (with standard solutions)
Cable Length:Standard: 10 m fixed cable at sensor
Cable Length 2:Optional Extensions: 7.6 m (25 ft.), 15.2 m (50 ft), or 30.5 m (100 ft.)
Maximum Total Length: 100 m (328 ft.)
Calibration Method:Sensor code for sensor cartridge, 1 and 2-point matrix correction
Certifications:CE approved
Construction - Sensor Body (RD 242/262):316 stainless steel with Ryton® ends
Data Transfer:current output, relays and bus communication via sc controller
Diameter:1.7 in ( 44 mm )
Dimensions (D x L):1.73 in x 13.78 in (44 mm x 350 mm)
Flow:< 4 m/s max. velocity
Installation Angle:45 ° ± 15 ° (vertical in flow direction)
Lower Limit of Detection (LOD):0.2 mg/L NH4–N
Material:Wetted materials: Only immersed installation. Sensor body stainless steel 316, ends of Ryton PPS®2.
Measurement Method:Ion-selective electrodes for ammonium and potassium with pHD reference electrode and temperature sensor
Measuring Interval:continuous
Measuring Principle:Ion-selective electrodes for ammonium and potassium, pHD reference electrode and temperature sensor
Operating Temperature Range:-20 to 45 °C (-4 to 113 °F)
pH Range:5 to 9 pH
Power Consumption:1
Pressure Limit:3.10 bar (45 psi) max. air pressure for cleaning unit option
Range:0.2 to 1000 mg/L NH4–N
Repeatability:5 % of measured value +0,2 mg/l (with standard solutions)
Response Time:< 2 min (T90)
Sample Flow Rate:Sensor Immersion Depth 0.3 to 3.0 m (1 to 10 ft); 0.3hPa (4.4 psi) pressure
Sample Temperature:0 to 40 °C (35 to 104°F)
Sensor Immersion Depth:0.3 to 3.0 m (1 to 10 ft.) max; 0.3 hPa (4.4 psi) pressure
Storage Conditions:5 °C to 40 °C
Warranty:2 years