产品中心
Product Center
热门搜索:
NPW-160在线TP/TN/COD分析仪 可同时测量TP、TN、COD
SDI-47手动SDI污染指数测定仪
Labsen 241-6SANXIN 半微量样品PH电极
GTDO-500PPB在线微量溶氧仪
GT SDI国产SDI污染指数测定仪
GTPH30经济型便携式PH测定仪
GTOX-700便携式微量溶氧分析仪
GTOX-610经济型便携式微量溶氧仪
GTCON30便携式电导率/TDS/盐度仪
9385100DR900便携式多参数水质分析仪
GTDR系列多功能数控消解仪
哈希总磷试剂
GTAT SDI全自动污染指数测定仪
GTPH40台式pH/ORP计
58700-34PC II硅离子水质分析仪 1-100mg/L SiO2
哈希余氯试剂
当前位置:首页
产品中心
水质分析仪器
其他水质分析仪及配件
6010101

6010101
产品简介
product
产品分类A simplified two-module design includes the sensor and the controller interface. The controller accepts two turbidity sensors€”adding a second 1720E sensor makes a system with two complete turbidimeters. Connections are simple plug & play.
The 1720E Turbidimeter uses the sc200 Controller to receive data from up to two sensors. A built-in data logger collects turbidity measurement at user selectable intervals (1-15 minutes), along with calibration and verification points, alarm history, and instrument setup changes for 6 months. Communications using MODBUS®/RS485, MODBUS®/RS232, LonWorks® protocols or the wireless IR port are available. The sc200 Controller is also compatible with AquaTrend® Networks. Local display, recall, graphing, and trending in CSV format make chart recorders redundant.
Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance. One controller accepts up to two plug and play sensors giving you two complete turbidimeters. Sensitive to fine changes in low level turbidity with a built-in bubble removal system. Built-in datalogger stores up to 6 months of data. Versatile digital output-MODBUS protocol, LonWorks or wireless IR port. Two year warranty.
The 1720E Turbidimeter reflects 45 years of Hach leadership in turbidity measurement science. Hach has the largest turbidimeter installation base in the world. And, Hach offers a two-year warranty on the 1720E.
1720E, 1720E User Manual, and 1000 mL 20 NTU StablCal ®.
Accuracy:(Defined according to ISO 15839.
±2% of reading or ±0.015 NTU (whichever is greater) from 0 to 40 NTU ; ±5% of reading from 40 to 100 NTU
Accuracy 2:±5% of reading from 40 to 100 NTU
Alarm:Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac; built into the sc200 Controller
Certifications:Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1
Communication:Network card compatible; MODBUS®/RS485, MODBUS/RS232, PROFIBUS, HART
Compliance:Standard Methods 2130B, USEPA 180.1, Hach Method 8195
Dimensions (H x W x D):10 in x 12 in x 16 in (254 mm x 305 mm x 406 mm)
Drain Fitting:1/2 NPT female, 1/2 hose barb (provided)
Enclosure Rating:NEMA 4X/IP66
Flow Rate:Sample Inlet Fitting: 1/4 NPT f, 1/4 compression fitting (provided)
Number of Alarms:Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac; built into the sc100 Controller
Operating Humidity:5 to 95 % non-condensing
Operating Temperature Range:0 to 40 °C (Double Sensor System)
Outputs:Recorder Two selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc100 Controller
Power Requirements (Hz):50 - 60 Hz
Power Requirements (Voltage):100 - 230 V AC
Range:0.001 to 100 Nephelometric Turbidity Units (NTU)
Repeatability:(Defined according to ISO 15839.)
Better than ± 1.0 % of reading or ±0.002 NTU, whichever is greater
Response Time:Initial response in 1 minute, 15 seconds for a full-scale step change
Sample Flow Rate:200 to 750 mL/minute (3.1 to 11.9 gal/hour)
Sample Temperature:0 to 50 °C (32 to 122 °F)
Shipping Weight:1720E Turbidimeter and sc100 Controller:
6.12 kg (13.5 lbs.)
Signal average time:User selectable from 6, 30, 60, 90 seconds; default 30 seconds
Storage Conditions:-20 °C to 60 °C
- See more at: http://www.hach.com/1720e-low-range-process-turbidimeter-turbidity-sensor-only/product-details?id=7640457219&callback=qs#sthash.p47wIYLN.dpuf